拖令电缆-拖令动力/控制电缆-上海拖令动力/控制电缆
拖令系统(动力/控制)用电缆
Festoon systems (power / control) cables
一.产品标准 Standard
技术规范:06-2003
Technical specification: 06-2003
二.用途 Application
适用于港口起重设备的拖令用系统。
Applicable to festoon system of port equipment.
三.结构 Construction
四 型号、名称 Type、Description
型号、电压级 Type、Voltage |
名称 Description |
0.6/1KV |
拖令系统用电缆
Festoon systems cables |
五.性能 Performance
1.电缆导体长期允许工作温度为100℃,户外温度-35℃,电缆最小弯曲半径为6D,
并具备高耐磨、耐臭氧、耐油、阻燃、抗紫外线和潮湿的特性。(D为电缆直径)
The cables permissible Long-term working temperature is 100℃, it can work under the
lowest temperature -35℃. Minimum bending radius is 6 D of the diameter of the cable,
and is high abrasion resistance, ozone resistance, oil resistance, flame retardant,
ultraviolet radiation and moist characteristics. (D =cable diameter)
2.电缆额定电压U0/U为300/500V。
The rated voltage of cable is 300/500V
3 .电缆的绝缘层为TPEE混合物,内护套采用TPE(单芯动力电缆无内套),外护套采用PUR混合物。
Insulation layer of Cable for TPEE mixture, inner sheath used TPE(not inner sheath for single core cable), outer sheath used PUR mixture.
4.电缆绝缘线芯为黑色,用白色数字连续编号,其中有一芯为绿/黄色保护接地芯。
The cores of cables is black, white codes with consecutive numbers, which includes a core Green / yellow earth core. The cable sheathing layer is black.
六、部分电缆规格 Specification
标称截面
Nominal cross section
mm2 |
结构组成
Construction
mm
|
绝缘厚度
mm |
内套
厚度
mm |
外护套
厚度
mm |
电缆标称外径
Nom.OD of cable
mm |
电缆外径
Max. OD
of cable
mm |
12×1.5 |
12×48/0.20 |
0.4 |
1.0 |
1.5 |
15.1 |
16.6 |
备注:因电缆规格较多,只列出部分供参考,其余的规格请来电咨询。我公司可根据客户需求,定做各种规格的电缆。